日韩综合图区|国产成人精品a视频一区|国产亚州精品女人久久久久久|亚洲国产精品日韩专区AV|囯产精品久久久久久久久久妞妞|欧美日韩国产在线人成

Multiparameter Meters

Bante903 Benchtop pH/Dissolved Oxygen Meter

High-precision multiparameter water quality meter contains measurement modes for pH, mV, ORP and dissolved oxygen, the setup menu offers 11 customizable options.

pH Mode:
? Multiparameter water quality meter is equipped with a large backlit LCD display.
? 1 to 5 points calibration with automatic recognition for USA, NIST and DIN buffers.
? Automatic electrode diagnosis shows the pH slope and zero offset.

pH Dissolved Oxygen Meter

ORP Mode:
? 1 point offset calibration allows adjusting the displayed value to a known standard.
? Relative and absolute millivolt modes ensure the reliable ORP measurements.

Dissolved Oxygen Mode:
? 1 or 2 points calibration using the air-saturated water or zero oxygen solution.
? Salinity and barometric pressure compensations eliminate measurement errors.

pH Dissolved Oxygen Meter

Other Features:
? Automatic temperature compensation ensures accurate readings over the entire range.
? Auto-read function senses and locks the measurement endpoint.
? Calibration due alarm reminds user to calibrate the meter regularly.
? Setup menu allows setting the number of calibration points, stability criteria, temperature unit,
  date and time, auto-power off, etc.
? Reset function automatically restores all settings to the factory defaults.
? Expanded memory stores or recalls up to 500 data sets.
? USB communication interface enables easy data transfer and timed interval readings.

   Model


Bante903

   pH



   Range


-2.000 to 20.000 pH

   Resolution


0.001 / 0.01 / 0.1 pH, selectable

   Accuracy


±0.002 pH

   Calibration


1 to 5 points

   pH Buffer Options


USA / NIST / DIN / 2 custom buffers

   ORP



   Range


-1999.9 to 1999.9 mV

   Resolution


0.1 / 1 mV, selectable

   Accuracy


±0.2 mV

   Calibration


1 point

   Measurement Modes


Relative / Absolute mV

   Dissolved Oxygen



   Range


0.00 to 20.00 mg/L / 0.0 to 200.0 % saturation

   Resolution


0.01 / 0.1, selectable

   Accuracy


±0.2 mg/L / ±2.0 %

   Calibration


1 or 2 points

   Pressure Correction


60.0 to 112.5 kPa / 450 to 850 mmHg, manual

   Salinity Correction


0.0 to 50.0 g/L, manual

   Temperature



   Range


0 to 105°C / 32 to 221°F

   Resolution


0.1°C/°F

   Accuracy


±0.5°C / ±0.9°F

   Calibration


1 point

   Calibration Range


Reading ±10°C/°F

   Other Specifications



   Temperature Compensation


0 to 100°C / 32 to 212°F, manual or automatic

   Hold Function


Manual / Auto-read measurement endpoint

   Stability Criteria


Low / High

   Calibration Due Alarm


1 to 31 days or off

   Memory


Stores up to 500 data sets

   Output


USB communication interface

   Connector


BNC, 6-pin mini-DIN, 3.5 mm jack socket

   Display


Custom LCD (125 × 100 mm)

   Power Supply


5V DC power adapter

   Environmental Conditions


0 to 50°C / 32 to 122°F, relative humidity < 80%

   Dimensions


210 × 188 × 60 mm

   Weight


1.5 kg

   Ordering Code

Meter Includes

   Bante903-CN

E201-BNC pH electrode

DO100 dissolved oxygen electrode

TP-10K temperature probe

pH 4.01, 7.00, 10.01 buffer reagents

DO electrolyte solution

DO membrane cap

USB cable

5V DC power adapter

   Bante903-UK

   

P11 glass pH electrode

DO100 dissolved oxygen electrode

TP-10K temperature probe

pH 4.01, 7.00, 10.01 buffer reagents

DO electrolyte solution

DO membrane cap

USB cable

5V DC power adapter

Items Description
E201-BNC pH Electrode For measuring the liquids
E202-BNC pH Electrode For measuring the semisolid and gel samples
P11 pH Electrode For measuring the weak corrosive samples
P11-LiCl pH Electrode For measuring the non-aqueous samples
P11-HA pH Electrode For measuring the high alkalinity samples
P11-NA pH Electrode For measuring the biofuels
P13 pH Electrode For measuring the micro-volume samples
P15 pH Electrode For measuring the low conductivity samples
P16 pH Electrode For measuring the Tris buffers
P19 pH Electrode For measuring the semisolid samples
501 ORP Electrode For measuring samples with weak redox potential
502 ORP Electrode For measuring samples with strong redox potential
DO100 Dissolved Oxygen Electrode For measuring the DO and % saturation of oxygen
TP-10K Temperature Probe For temperature compensation and measurement
pH Buffer Solution For pH calibration
pH Electrode Storage Solution For electrode maintenance and storage
pH Electrode Cleaning Solution For electrode cleaning and reactivating
DO Electrolyte Solution For filling the dissolved oxygen electrode
DO Membrane Cap For polarographic dissolved oxygen electrode

   Ordering Code

Dimensions and Weights

   Bante903-CN

30 × 25 × 20 cm, 1.7 kg

   Bante903-UK

30 × 25 × 20 cm, 1.7 kg

日韩综合图区|国产成人精品a视频一区|国产亚州精品女人久久久久久|亚洲国产精品日韩专区AV|囯产精品久久久久久久久久妞妞|欧美日韩国产在线人成 莱芜市| 突泉县| 武清区| 普兰店市| 郎溪县| 新乡市| 长葛市| 潜山县| 开鲁县| 吉首市| 辛集市| 诸城市| 石林| 杭州市| 随州市| 祥云县| 大港区| 杨浦区| 沂源县| 石门县| 金川县| 剑川县| 武功县| 岗巴县| 比如县| 若尔盖县| 洪雅县| 株洲市| 青州市| 金湖县| 天镇县| 米泉市| 内江市| 章丘市| 陈巴尔虎旗| 潢川县| 枞阳县| 潞城市| 金阳县| 南陵县| 洛隆县| http://444 http://444 http://444 http://444 http://444 http://444